Arc Premier LC System

0 reviews 0 questions

Thanks to the Arc Premier System, combined with the latest MaxPeak HPS technologies, we continue to deliver the product quality you expect and the best possible results. High-Performance Analytical Detectors The system offers a wide range of detection capabilities, including a TU...

Turnkey supply, installation and training · Service across Ukraine

Thanks to the Arc Premier System, combined with the latest MaxPeak HPS technologies, we continue to deliver the product quality you expect and the best possible results.

High-Performance Analytical Detectors

The system offers a wide range of detection capabilities, including a TUV detector, PDA, FLR, RI detector, ELS, and single- and triple-quadrupole mass spectrometry detectors.

Solvent mixing

A binary or four-channel pump (optional) ensures precise solvent mixing at pressures up to 9,500 psi. An optional solvent selection valve provides access to additional solvents. Automatic solvent compression compensation, integrated solvent degassing, and programmable seal flushing ensure maximum flow accuracy.

Versatile Column Control

Suitable for analytical columns up to 300 mm in length with automated switching between six columns using an optional column manager. Equipped with zone temperature control, solvent preheating, and eCord™ Intelligent Chip technology for each column. The column temperature can be maintained within the following ranges (depending on the type of column manager):
  • from 20.0 °C to 90.0 °C;
  • from 4.0 to 90.0 °C.

Sample Manager

The sample manager uses a “flow-through-needle” (FTN-R) design to aspirate samples and hold them in the needle while preparing the sample for injection into the column. The needle becomes part of the flow path, so the mobile phase flushes the needle during the cycle, ensuring complete sample recovery and minimizing carryover. The standard configuration supports injection volumes of 0.1–50 μL. Additional extension loops can increase the volume up to 1,000 μL. Sample temperature is maintained within the range of 4° to 40°C.

SmartStart Gradient System

With the SmartStart system, you can transfer analysis methods between instruments without changing the gradient table, as the system automatically calculates the required retention time based on the new conditions.