ACQUITY Premier System

0 reviews 0 questions

The ACQUITY Premier system is the next evolution of the Performance LC System, which includes the ACQUITY UPLC H-Class PLUS and ACQUITY UPLC I-Class PLUS systems. In addition to the reliability, durability, high quality, and configuration flexibility you expect from the ACQUITY U...

Turnkey supply, installation and training · Service across Ukraine

The ACQUITY Premier system is the next evolution of the Performance LC System, which includes the ACQUITY UPLC H-Class PLUS and ACQUITY UPLC I-Class PLUS systems. In addition to the reliability, durability, high quality, and configuration flexibility you expect from the ACQUITY UPLC PLUS series, the ACQUITY Premier system delivers a significant leap in chromatographic performance, laboratory efficiency, and risk management.

High-Performance Analytical Detectors

The system offers a wide range of detection options, including a TUV detector, PDA, FLR, RI detector, ELS, and single- and triple-quadrupole mass spectrometry detectors.

Solvent mixing

A binary or four-channel pump (optional) ensures precise solvent mixing at pressures up to 15,000 psi. Automatic solvent compression compensation, integrated solvent degassing, and programmable seal flushing ensure maximum flow accuracy. The operating flow range is 0.001 to 2,000 mL/min for the binary pump and 0.001 to 2,200 mL/min for the four-channel pump.

Versatile column control

Suitable for analytical columns up to 300 mm in length with automated switching between six columns (150 mm in length) using an optional column manager. Equipped with temperature zone control, solvent preheating, and eCord™ Intelligent Chip technology for each column. The column temperature can be maintained within the following ranges (depending on the type of column manager):
  • from 20.0 °C to 90.0 °C;
  • from 4.0 to 90.0 °C.

Sample Manager

Two sample manager designs are available:
  • “flow-through-needle” (FTN) for aspirating samples and holding them in the needle while preparing the sample for injection into the column. The needle becomes part of the flow path, so the mobile phase flushes the needle during the cycle, ensuring complete sample recovery and minimizing carryover. The standard configuration supports injection volumes of 0.1–10 μL. Additional extension loops can increase the volume up to 1,000 μL.
  • The FL “fixed loop” supports injection volumes ranging from 0.1 μL to 250.0 μL in 0.1 μL increments. The standard configuration includes a 10 µL loop with additional loops of 1, 2, 5, 20, 50, 100, and 250 µL.
The sample temperature is maintained within a range of 4° to 40°C.